|
|
Nitrate
- tester, radioactivity indicator "Ecotester"
Short
description. A nitrate-tester is intended
for the estimation (express-analysis) of content
of nitrates in fresh vegetables and fruit in home
conditions. Not used for vegetables and fruit,
passing treatment (drying, freezing, preservation,
and other). An analysis is produced on the basis
of measuring of conductivity of alternating high-frequency
current in a measureable product.
Also a device is intended for the estimation of
value of radiation background (radiations) from
surrounding objects. For this purpose the SBM-20
Geiger counter is set inside device.
A device is equipped a colour display, allowing
to consider information, both in a numerical and
graphic mode. Under a display 4 navigation buttons
are located and button «OK».
A removable cap, protecting from casual contiguities
with a sharp measuring probe, is located in an
underbody. A contact with an analysable product
is performed by a measuring probe, located under
a cap. From the back a battery compartment is
located. The power supply of device is carried
out from a 2 batteries size "AAA".
A nitrate-tester
allows to conduct measurings in more than 30 types of green-stuffs
and fruit, including: apricot, water-melon, egg-plant, banana,
grape, pear, greenery, melon, cheap restaurant, cabbage, potato,
strawberry, bow, mango, carrot, nectarines, cucumber, pepper,
tomato, garden radish, lettuce, beet, persimmon, apple, meat.
Switch
on. For the nitrate sensor power supply the 2 batterøó³ is
intended from the complete set of delivery. If to retain the button
of including in the pushed-in state, a device will be switch on
(at including during 3 seconds illumination of producer is demonstrated
and a main menu appears).
Switch
off. A device is automatically switched off through time,
set in a menu: «Tuning of Auto Off.» This parameter in seconds
sets a time through which automatically the shutdown of nitrate-tester
will happen in case of absence of pressures on any button. It
is othergates possible to turn off a nitrate-tester continuously
pushing button of shutdown during a 1th second. In default of
necessity for the use of nitrate-tester, it is recommended to
extract the power supply elements from him.
State
of power supply elements. In the mode of reflection of
menu character of element of battery on which it is possible to
define the remain of charge of batteries is represented in the
right overhead corner of screen. The size of inundation of rectangle
is proportional tension on batteries (accumulator), a color is
determined by the state of batteries: a green color means that
batteries are "fresh" and suitable to the use; the yellow
talks that batteries are week, but yet a bit able to do some work,
if an accumulator is set, it is better to recharge him; the red
color of inundation designates that batteries are discharged,
measuring results can be unreliable, replacement of batteries
or urgent charging of accumulator is required.
Menu.
In the mode of reflection of menu a screen is divided into three
parts: overhead part of screen - informative. The current level
of menu, state of batteries (accumulator), is here represented.
Middle part of screen - actually menu. There is a pointer of current
element in the left column of pointer, on the right will substitute
the pointer of presence or implementations of the indicated function.
Underbody - auxiliary. Destination of the buttons is here represented,
and on the right is the pushed-in presently button.
Three parts of screen part lines by delimiters. If there is part
of menu, not represented on the screen, in an overhead line delimiter
or in a lower line delimiter the proper pointer will appear.
Measuring
of content of nitrates. For the leadthrough of measuring
of content of nitrates in vegetables, fruit or other products
will execute follow actions:
-
Choose in menu "Nitrate-tester"
mode and select the checked product. Product
must be clean, without dirt on the surface.
Washing a product is needed without the
use of cleansers, and only simple clean
water. A product must not be spoilt slightly
a rot, on the surface must not be tracks
from hits or bites of rodents. A product
must not be dried-up, must have a healthy,
appetizing kind. It is possible to use
the cuts of products, but a cut must be
fresh, with a term no more than 15 minutes.
-
After
the choice of product text must appear
on the screen: «you will make sure, that
a probe will not be stuck in the checked
up product».
-
Push
the button “OK”. Thus preparation to measurings
will starts (self calibration). Wait till
appearance of invitation to the further
actions. During expectation on the screen
text will be present «Wait, preparation
goes to measurings». At this time touching
the probe is forbidden.
-
Stick a probe in the checked product.
Sticking a probe is necessary maximally
athwart planes of product, desirably,
towards his center. It is not needed to
turn a probe into a product, to press
on a product. A depth of input of probe
can be from 10 mm to complete immersion
in the checked product. The sharp end
of probe must not go out outside from
a product outside, opposite the place
of input in an examinee body. The end
of probe must not get in the area of ripening
of seed, in the district of stone, in
internal emptinesses, and must be in even
soft juicy mass of product, most often
used in food. Do not use opening, leave
in the checked up product as a result
of sticking in him of probe of tester
or other objects repeatedly.
-
Push the button "OK". A measuring
process will begin.
-
Wait
till appearance of results of measurings.
During expectation there will be text
on the screen: «Wait, measuring goes».
At this time forbidden to move a probe
inside a product.
-
Memorize
measuring results. Except for a digital
value one of four inscriptions will be
represented: «Content of nitrates in a
norm», «Insignificant exceeding of norm»,
«Impermissible concentration of nitrates».
-
Take
off a probe from an examinee product,
wipe it and push the button for a return
in a menu (if during measurings long not
to press on a keyboard, a device automatically
will be turned off).
Radioactivity
measurement. For measuring radio-activity
it is enough in a menu to enter in the mode "Radio-activity"
and to bring a device as possible nearer to the
interesting you object on 20-30 seconds. Thus
on the screen the current value of radiation background
will be continuously represented and to hatch
the proper report (for example, "Radiation
background in a norm" - at unexceeding of
the set threshold). A threshold can be changed
if necessary.
|